Adhesive Details


** The actual package type may not be the same as shown in the photo **
|
USG713
|
Characteristics
USG713 is room temperature moisture curable conformal coating. It is one-component, solvent-free coating compound. After cure, it forms a rubbery layer with excellent adhesion to most substrates, which provides protection for electronic devices. USG713 is best applied by spraying or dipping. A coating thickness of 5 to 10 mils is recommended for best results.
Special Features and Benefits
• One part ready to use
• Solvent free (100% solid)
• Room temperature moisture cure
• Bond to various substrates
• Strong media resistance
• Flexible over -40°C to 180°C
• Excellent dielectric property
• Low thermal stress
Typical Applications
• Protection of electronic components / devices
• For harsh environment applications
• Water resistant coating
• Automotive electronics
• Semiconductor and telecommunications
• Low thermal stress coating

Click here to view the Technical Datasheet (TDS) of this product in details (PDF File) »
Processing Instruction
Important! To reach best results, the coating surface needs to be clean and free of oil, grease, lubricants, soaps, dust, mold release agents, etc. Cure time will vary depending on exposure conditions, For instance, a 5 mil thick coating cured under 50% R.H. at 25°C will need ~25 minutes to cure through.
We recommend running preliminary tests to optimize conditions for the particular application. The cure of 713 may be accelerated with a higher humidity and temperature. Recommendations for automated dispensing equipment and accelerated cure profiles can be obtained by contacting directly to USGlue.com.
Storage
USG713 has a shelf life of at least 12 months when stored at ambient (< 25°C) in the originally sealed container. Storage beyond the date specified does not necessarily mean that the product is no longer usable. In this case however, the properties required for the intended use must be checked for quality assurance reasons.
Safety information
USG713 silicone releases low content of oxmine volatile by-product in cure process when it is exposed to moisture. Please use adequate ventilation in its cure stage. General hygiene regulations should be observed. Comprehensive instructions are given in the corresponding Material Safety Data Sheets that are available on request from USGlue.com.
The data presented in this leaflet are in accordance with the present state of our knowledge, but do not absolve the user from carefully checking all supplies immediately on receipt. We reserve the right to alter product constants within the scope of technical progress or new developments. The recommendations made in this leaflet should be checked by preliminary trials because of conditions during processing over which we have no control, especially where other companies’ raw materials are also being used. The recommendations do not absolve the user from the obligation of investigating the possibility of infringement of third parties’ rights and, if necessary, clarifying the position. Recommendations for use do not constitute a warranty, either express or implied, of the fitness or suitability of the products for a particular purpose. For technical, quality, or product safety questions, please contact directly to USGlue.com.
|
|
 |
|